| Applications | Specifications | |
|
Biacore T100 Stefan Schauer Jens Sobek |
Kinetic and thermodynamic characterization of biomolecular interactions covering, but not limited to: protein - protein protein - peptide protein - small molecule protein - DNA protein - RNA protein - tRNA protein - carbohydrate protein - lipid protein - virus protein - cell interactions and permutations thereof. The system is exceptionally suited for method development, proof of principle, high sensitivity and low noise requiring measurements. |
Detection System: Number of flow cells: 4 Refractive index range: 1.33 - 1.39 refractive index units (RIU) Dynamic range: 1 - 60000 response units (RU) Baseline noise: <0.1 RU Baseline drift: <0.3 RU/min Experiment temperature range: 4 - 45 ºC Detection Limits: Molecular Weight detection limit: 100 daltons Conentration detection limit: pM - mM levels (dependent on ligand density, affinity constants, and molecular weights of both, ligand and analyte) Working Range: Association rate constant, ka: 10xE03 - 10xE07 /Ms Dissociation rate constant, kd: 10xE-05 - 0.5 /s Fluidics: Sample handling: automatic/programmable Sample injection volume: 2 - 350 µl Flow rate range: 1 - 100 µl/min Online degasser |
|
ProteOn XPR36 Stefan Schauer Jens Sobek |
Array system for multiplexed SPR data acquisition. Covers high throughput needs like compound library screening (small molecules, antibodies, DARPins etc.) |
Detection System: Number of interaction spots: 36 Refractive index range: 1.33 - 1.37 refractive index units (RIU) Dynamic range: 1 - 40000 response units (RU) Baseline noise: <1 RU Baseline drift: <1 RU/min Experiment temperature range: 15 - 40 ºC Detection Limits: Molecular Weight detection limit: 200 daltons Conentration detection limit: nM - mM levels (dependent on ligand density, affinity constants, and molecular weights of both, ligand and analyte) Working Range: Association rate constant, ka: 3xE03 - 10xE06 /Ms Dissociation rate constant, kd: 5xE-05 - 0.6 /s Fluidics: Sample handling: automatic/programmable Sample injection volume: 25 - 449 µl Flow rate range: 25 - 100 µl/min Online degasser |
Specific, reversible interaction between two molecules is a phenomenon from which there is no escape in any field of biology. For example, an understanding of metabolism at the molecular level requires the quantitative consideration of a vast array of interactions between enzymes and
substrates, cofactors, inhibitors and effectors. Antigen-antibody interactions are central to immunology. Control of gene expression and protein synthesis entails a maze of interactions between proteins and nucleic acids. Signal transduction through biomembranes relies upon a cascade of events involving recognition and binding of cellular constituents. Furthermore, the interactions of proteins, hormones, drugs or other ligands with matrix proteins and membrane receptors control widely divergent cellular events such as muscle contraction, blood coagulation,
hormone response and lymphocyte activation. In other words, binding events are the essence of biological control. A feature of these binding phenomena is the non-covalence of the interactions, the equilibrium nature of which allows the extent of complex formation to vary with prevailing reactant concentrations and hence with fluctuations in the metabolic state of the cell. A prerequisite for biological relevance of an interaction is the demonstration of a significant extent of complex formation in mixtures with reactant concentrations that are likely to prevail in the physiological environment. The usual way of establishing such significance is to measure the binding constant governing the equilibrium, thereby allowing the composition of an equilibrium mixture to be predicted for any specified combination of reactant concentrations by applying the law of mass action.
Our two surface plasmon resonance (SPR) based instruments, a Biacore T100 and a ProteOn XPR36, measure the changes in angle of deflection of the evanescent internal absorbance of plane-polarized monochromatic light. This deflection angle is sensitive to picogram levels of analyte that are flowing over a surface with immobilized ligand. Based on surface density variation, the signal differentiates between bound and unbound analyte. The response of the instrument is mass proportionate, and the plot of response versus time (a sensorgram) can be fit to a variety of kinetic models to calculate kinetic rate constants and reaction affinity.
Wichtiger Hinweis:
Diese Website wird in älteren Versionen von Netscape ohne
graphische Elemente dargestellt. Die Funktionalität der
Website ist aber trotzdem gewährleistet. Wenn Sie diese
Website regelmässig benutzen, empfehlen wir Ihnen, auf
Ihrem Computer einen aktuellen Browser zu installieren. Weitere
Informationen finden Sie auf
folgender
Seite.
Important Note:
The content in this site is accessible to any browser or
Internet device, however, some graphics will display correctly
only in the newer versions of Netscape. To get the most out of
our site we suggest you upgrade to a newer browser.
More
information