printlogo
http://www.ethz.ch/index_EN
Functional Genomics Center Zurich
 
print
  

Mass Spectrometers

Quicklinks

Intranet: Info and Docu

Project: Request Projects

Order: Order Services

  Applications Specifications
AB Sciex 5600
TripleToF


Bernd Roschitzki
Gel / LC-MS/MS
LC-MS/MS (MudPIT)
Intact proteins
Labeled and label-free quantitative proteomics
Hybrid mass spectrometer
Quadrupole–Time-of-Flight Mass Analyser
High scan speed (up to 50 MS/MS per sec) with high resolution (>20’000 FWHM) and high mass accuracy (2ppm)
Fragmentation: CID
HPLC: Eksigent UPLC 1D plus
Software: Analyst TF
AB Sciex 5500
Q-TRAP


Asa Wahlander
Targeted analysis (SRM/MRM)
Neutral loss scan analysis
Precursor scan analysis
LC-MS/MS (MudPIT)
Absolute and relative quantification
Hybrid mass spectrometer
High sensitivity instrument
Triple Quadrupole Linear Accelerator Trap
Fragmentation: CID
HPLC: Eksigent UPLC 1D plus
Software: Analyst
LTQ-Orbitrap Velos

Asa Wahlander
Gel / LC-MS/MS;
LC-MS/MS (MudPIT)
top-down proteomics
high accuracy MS/MS
PTM detection
Labeled and label-free quantitative proteomics
Hybrid mass spectrometer
Dual-Pressure Linear Ion Trap and Orbitrap
Resolution power: >100’000 @ 400 m/z
Mass accuracy: <3 ppm (extern. calibration)
<1 ppm (intern. calibration)
Fragmentation: PQD, CID, HCD
HPLC: Eksigent UPLC 1D plus with cHiPLC
Software: Xcalibur
LTQ-Orbitrap Velos ETD

Paolo Nanni
Gel / LC-MS/MS;
LC-MS/MS (MudPIT)
top-down proteomics
high accuracy MS/MS
PTM detection
Labeled and label-free quantitative proteomics
Hybrid mass spectrometer
Dual-Pressure Linear Ion Trap and Orbitrap
Resolution power: >100’000 @ 400 m/z
Mass accuracy: <3 ppm (extern. calibration)
<1 ppm (intern. calibration)
Fragmentation: PQD, CID, HCD, ETD
HPLC: Eksigent UPLC 1D plus with cHiPLC
Software: Xcalibur
Thermo TSQ Quantum

Endre Laczko
SRM
Metabolome analysis
Triple Quadrupole Mass Spectrometer
Thermo TSQ Vantage

Endre Laczko
SRM
Metabolome analysis
Triple Quadrupole Mass Spectrometer
Waters GCT Premier

Endre Laczko

Stefan Schauer
Metabolome analysis GC-TOF Mass Spectrometer
LTQ-FT-ICR Ultra

Bernd Roschitzki
Gel / LC-MS/MS
LC-MS/MS (MudPIT)
top-down proteomics
high-resolution MS PTM detection, SILAC, ICAT, ICPL, label-free proteomics
Hybrid mass spectrometer
2D ion trap and Fourier transform ion cyclotron resonance MS (ICR)
Resolution power: 1’000’000 @ 400 m/z
mass accuracy: <2 ppm (extern. calibration)
Fragmentation: PQD, CID
HPLC: Eksigent 2D
Autosampler: Spark Holland
Software: Xcalibur
LTQ-Orbitrap XL ETD

Paolo Nanni
Gel / LC-MS/MS;
LC-MS/MS (MudPIT or RP/RP)
top-down proteomics
high accuracy MS/MS
Electron Transfer Dissociation (ETD)
PTM detection
ICAT, iTRAQ, label-free proteomics
Hybrid mass spectrometer
2D ion trap, Orbitrap and HCD collision cell;
Resolution power: 100'000 @ 400 m/z
Mass accuracy: <5 ppm (extern. calibration)
<1 ppm (intern. calibration)
Activation: ETD, HCD, PQD and standard CID
Pump: Eksigent 1D plus
Autosampler: Spark
Software: Xcalibur
LTQ-Orbitrap

Peter Gehrig
Gel / LC-MS/MS;
LC-MS/MS (MudPIT)
top-down proteomics
high accuracy MS/MS
PTM detection
ICAT, Silac, label-free proteomics
Hybrid mass spectrometer
2D ion trap and Orbitrap
Resolution power: 100’000 @ 400 m/z
Mass accuracy: <5 ppm (extern. calibration)
<1 ppm (intern. calibration)
Activation: PQD, CID
Pump: Eksigent 1D plus
Autosampler: Spark
Software: Xcalibur
Waters QTOF G2 HDMS

Endre Laczko
Metabolome analysis, lipid analysis,
analysis of whole protoeins, analysis of non-covalent protein-ligand and protein-protein interactions, MS^e analysis,
label-free proteomics
Resolution power: 40’000
Mass accuracy: 1 ppm
Ion mobility separation
Activation CID
Pump: Waters nanoAcquity UPLC
Software: MassLynx, ProteinLynx Global Server
LTQ

Bernd Roschitzki
Gel / LC-MS/MS;
LC-MS/MS (MudPIT)
High throughput proteomics
(C-MOP)
large scale analysis
2D linear ion trap
high scan rate
Pump: Ultimate
Autosampler: FAMOS
Software: Xcalibur
ABI 4800 MALDI TOF/TOF™

Peter Gehrig
- Analysis of complex proteome samples by liquid chromatography
- MALDI mass spectrometry (LC-MALDI-MS)
- Peptide and protein quantification using iTRAQ reagents
- Studies of protein phosphorylation and of other post-translational modifications
- Structural characterization of oligosaccharides, glycans, lipids and of other biomolecules
Tandem time-of-flight mass spectrometer
Detection limit: Medium attomole range
Mass accuracy: < 35 ppm (ext. calibration)
< 10 ppm (int. calibration)
Software: 4000 Series Explorer
Bruker Ultraflex

Protein Service:
Rene Brunisholz
Mass determination of intact biopolymers
Protein identification of low complex samples
- peptide mass finger printing (PMF)
- MALDI-MS/MS
Protein identification of complex samples
- LC-MALDI-MS/MS
Structural analysis (MS/MS) of peptides
Top-down proteomics
Carbohydrate analysis
Smart beam upgrade
HPLC: Agilent 1100 capLC, Agilent microspotter
Software: FlexControl, FlexAnalysis, Biotools
Bruker Autoflex

Protein Service:
Peter Hunziker
Mass determination of intact biopolymers
Protein identification of low complex samples
- peptide mass finger printing (PMF)
Software: FlexControl, FlexAnalysis, Biotools
Waters QTOF Ultima API

Protein Service:
Peter Hunziker
Mass determination of intact biopolymers
Mass determination of small molecules
Structural analysis (MS/MS) of peptides and small molecules
HPLC: Waters nano Aquity UPLC
Software: MassLynx, BioLynx, ProteinLynx Global Server
Waters QTOF G2 HDMS

UserLab:
Endre Laczko

Protein Service:
Peter Hunziker
Protein identification of complex samples
- LC- MS/MS (“shotgun proteomics”)
- Gel-LC-MS/MS
Protein identification of low complex samples
- LC-MS/MS
- Gel-LC-MS/MS
Structural analysis (MS/MS) of peptides
HPLC: Waters nanoAquity UPLC
Software: MassLynx, BioLynx, ProteinLynx Global Server
 

Wichtiger Hinweis:
Diese Website wird in älteren Versionen von Netscape ohne graphische Elemente dargestellt. Die Funktionalität der Website ist aber trotzdem gewährleistet. Wenn Sie diese Website regelmässig benutzen, empfehlen wir Ihnen, auf Ihrem Computer einen aktuellen Browser zu installieren. Weitere Informationen finden Sie auf
folgender Seite.

Important Note:
The content in this site is accessible to any browser or Internet device, however, some graphics will display correctly only in the newer versions of Netscape. To get the most out of our site we suggest you upgrade to a newer browser.
More information

© 2012 FGCZ Zurich | Imprint | Disclaimer | 23 November 2011
top